8-33
Classifier-Based Software Configuration
Traffic Classes
Resequencing Classes in a Policy
You can use the policy command with the resequence option to reconfigure
the number at which the first class-action statement starts, and reset the
interval used to number other class-actions.
Resequencing class-actions is useful when you want to insert a new class-
action between two numbered entries.
Note When you resequence class-action statements in a policy, the default class-
action-statement always remains as the last class-action statement.
To view the current class-action numbering in a policy, enter the show policy
< feature-name > < policy-name > command.
The following example shows how to resequence a policy configuration after
displaying its contents. The resequenced policy allows you to add a new class-
action statement between entries 100 and 200.
Context: Global configuration
Syntax: policy resequence <name> <seq-number> < interval >
resequence: Resets the sequence numbers for all class-action
statements in the policy.
<name>: Replace with the name of the policy that contains the
class-action statements that you want to resequence.
< seq-number >: Specifies the sequence number of the first class-
action-statement in the policy. Default: 10.
< interval >: Specifies the interval between sequence numbers of
class-action statements in the policy to allow additional
statements to be inserted. Default: 10.

Table of Contents

Other manuals for HP 3500 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP 3500 Series and is the answer not in the manual?

HP 3500 Series Specifications

General IconGeneral
ModelHP 3500 Series
LayerLayer 3
MAC Address Table Size16, 000 entries
TypeManaged
UplinkSFP
PoEOptional
ManagementWeb, CLI, SNMP
Routing ProtocolStatic, RIP
Power SupplyInternal
Form Factor1U rack-mountable
Jumbo Frame SupportYes
Operating Temperature32°F to 113°F (0°C to 45°C)
Ports24 or 48 10/100/1000 ports

Related product manuals