8-32
Classifier-Based Software Configuration
Traffic Classes
To modify the class-action statements in a policy, enter the policy-config-
uration context with the policy <feature-name > <policy-name > command.
(To display a policy configuration, enter the show policy < feature-name >
< policy-name > command as shown in Figure 8-11.) Then do one of the
following:
You can enter a new class-action statement. If you do not enter a
sequence number, the new class-action statement is inserted at the
end of the policy configuration.
To remove a class-action statement from a policy configuration, enter
the no <sequence-number > command or the complete form of the no
class ... action command.
To resequence the order in which class-action statements are listed,
enter the resequence command (see “Resequencing Classes in a Pol-
icy” on page 8-33).
To replace an existing class-action statement, enter the no <sequence-
number > command to delete the entry, and re-enter a complete class
< ipv4 | ipv6 > < classname > action < action-name > or default-class action
< action-name > command.
When you exit the policy-configuration context, the changes are automat-
ically saved and applied to the policy configuration if the policy has not
been applied to an interface. If the policy has already been applied to an
interface, the editing changes are not accepted and an error message is
displayed.

Table of Contents

Other manuals for HP 3500 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP 3500 Series and is the answer not in the manual?

HP 3500 Series Specifications

General IconGeneral
ModelHP 3500 Series
LayerLayer 3
MAC Address Table Size16, 000 entries
TypeManaged
UplinkSFP
PoEOptional
ManagementWeb, CLI, SNMP
Routing ProtocolStatic, RIP
Power SupplyInternal
Form Factor1U rack-mountable
Jumbo Frame SupportYes
Operating Temperature32°F to 113°F (0°C to 45°C)
Ports24 or 48 10/100/1000 ports

Related product manuals