3-75
Multiple Instance Spanning-Tree Operation
Loop Protection
Loop Protection in Port Mode
To enable loop protection in port mode, follow these steps.
1. Configure port mode with this command:
HP Switch(config)# loop-protect mode port
2. Enter the loop-protect command and specify the port(s) on which loop
protection should be enabled. For example:
HP Switch(config)# loop-protect 1-2
3. You can optionally specify a receiver-action of send-disable to shut down
the port in the event of a loop. For example:
HP Switch(config)# loop-protect 1-2 receiver-action
send-disable
Loop Protection in VLAN Mode
You can only configure VLANs for loop protection when operating in VLAN
mode. When loop-protect is enabled for a VLAN and a loop-protect enabled
interface is a member of that VLAN, loop protect packets are sent on that VLAN
to detect loops.
To enable loop protection in VLAN mode, follow these steps.
1. Configure VLAN mode with this command:
HP Switch(config)# loop-protect mode vlan
2. Enter the loop-protect command and specify the VLANs on which loop
protection should be enabled. For example:
HP Switch(config)# loop-protect vlan 20,30
Changing Modes
When changing from VLAN mode to port mode, you are prompted with a
message, as shown in Figure 3-35. The VLANs will no longer be configured for
loop-protection.
Configure the VLANs on which loop-protect is enabled.
Maximum number of loop-protected VLANS is 32.

Table of Contents

Other manuals for HP 3500 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP 3500 Series and is the answer not in the manual?

HP 3500 Series Specifications

General IconGeneral
ModelHP 3500 Series
LayerLayer 3
MAC Address Table Size16, 000 entries
TypeManaged
UplinkSFP
PoEOptional
ManagementWeb, CLI, SNMP
Routing ProtocolStatic, RIP
Power SupplyInternal
Form Factor1U rack-mountable
Jumbo Frame SupportYes
Operating Temperature32°F to 113°F (0°C to 45°C)
Ports24 or 48 10/100/1000 ports