OVERshoot
OVERshoot
command/query
The :MEASURE:OVERSHOOT
command
places
the
instrument
in the
continuous measurement
mode and selects
the
Overshoot
measurement.
The
OVERSHOOT
query measures
and
outputs
the
overshoot
of
a
selected
signal.
Overshoot
measures
the
first
edge
on
screen
with
the
following algorithm:
if
the
first
edge
on
screen
is
rising
then
overshoot
=
(Vmax
-
Vtop)/VampIitude
else
overshoot
=
(Vbase
Vmin)/Vamplitude
Command Syntax:
:MEASure:ovERshoot
Example:
OUTPUT
707;";MEAS:OVER"
Query
Syntax:
:MEASure:ovERshoot?
Returned Format:
[:MEASure:ovERshoot]
<value> <NL>
Where:
<
value
>
::
=
ratio
of
overshoot
to
Vamplitude (exponential
-
NR3 format)
Example:
DIM
Ow$[50]
OUTPUT
707;":MEASURE:OVERSHOOT?"
ENTER
707;0vr$
PRINT
Ovr$