WINDow:RANGe
WINDow:RANGe
(Timebase)
command/query
The
:TIMEBASE:WINDOW:RANGE
command
sets
the
full
scale
horizontal time
in
seconds
for
the
second
(expanded)
timebase.
The
RANGE
value
is
ten times
the
time
per
division
of
the
second
timebase.
The
WINDOW:RANGE
query
returns
the
current
range value.
Command
Syntax:
:TIMebase:WlNDow:RANGe
<
range
>
Where:
<
range
>
::
=
1
ns
to
50
s
(depends
on
main
sweep
setting)
Example:
OUTPUT
707;":TIM:W1ND:RANG
100
NS"
Query
Syntax:
:TIMebase:WINDow:RANQe?
Returned Format:
[:TIMebase:WlNDow:RANGe]
<range>
<NL>
Where:
<
range
>
::
=
1
ns
to
50
s
(depends
on
main
sweep
setting)
(exponential
-
NR3
format)
Example:
DIM
Wmg$[50]
OUTPUT
707;":TIMEBASE:WINDOW:RANGE?"
ENTER
707;Wrng$
PRINT
Wrng$