TSTArt
TSTArt
command/query
The :MEASURE:TSTART
command
moves
the
start
marker
to
the
specified
time
with
respect to
the trigger
time.
The TSTART
query
returns
the
time at
the
start
marker.
Note
The short
form
of
this
command
does
not
follow
the
defined
convention.
The
short
form
"TST'is the
same
for
TSTART
and
TSTOP,
so
be
careful
not
to
send
this
form
for the
TSTART
command.
Sending
"TST'
will
produce
an
error.
Command
Syntax:
:MEASure:TSTArt
<
start
marker time
>
Where:
<
start
marker
time
>
::
=
time
at start
marker
in
seconds
(exponential
-
NR3
format)
Example:
OUTPUT
707;":MEASURE:TSTART
30
NS"
Query
Syntax:
:MEASure:TSTArt?
Returned
Format:
[:MEASure:TSTArt]
<valuexNL>
Where:
<
value
>
::
=
time at
start
marker
in
second
(exponential
-
NR3
format)
Example:
DIM
Tst$
OUTPUT
707;":MEASURE:TSTART?"
ENTER
707;Tst$
PRINT
Tst$