Hardware options installation 68
15.
Power up the server.
After installing the DIMMs, use BIOS/Platform Configuration (RBSU) in the UEFI System Utilities ("HPE
UEFI System Utilities" on page 101) to configure the memory protection mode.
Dedicated iLO management module option
To install the component:
1. Power down the server (on page 17).
2. Remove all power:
a. Disconnect each power cord from the power source.
b. Disconnect each power cord from the server.
3. Place the server on its side.
4. Remove the access panel (on page 17).
5. If installed, remove the PCI air baffle (on page 20).
6. Remove the system air baffle (on page 21).
7. Open the slot cover retainer and remove the PCIe blank.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP HPE ProLiant ML110 Gen9 and is the answer not in the manual?

HP HPE ProLiant ML110 Gen9 Specifications

General IconGeneral
Processor Sockets1
Memory Slots8 DIMM slots
ProcessorIntel Xeon E5-2600 v3/v4
ChipsetIntel C610
MemoryDDR4 SmartMemory
StorageUp to 8 LFF or 16 SFF drives
Storage ControllerDynamic Smart Array B140i or P440ar
RAID SupportRAID 0, 1, 5, 10 with optional controller
Network1GbE
Expansion SlotsPCIe slots
Form FactorTower
Operating System SupportWindows Server, Red Hat Enterprise Linux, SUSE Linux Enterprise Server, VMware
Maximum Internal Storage16 TB