2-18
TACACS+ Authentication
Configuring TACACS+ on the Switch
Adding, Removing, or Changing the Priority of a TACACS+ Server.
Suppose that the switch was already configured to use TACACS+ servers at
10.28.227.10 and 10.28.227.15. In this case, 10.28.227.15 was entered first, and
so is listed as the first-choice server:
Figure 2-4. Example of the Switch with Two TACACS+ Server Addresses
Configured
To move the "first-choice" status from the "15" server to the "10" server, use
the
no tacacs-server host <ip-addr> command to delete both servers, then use
tacacs-server host <ip-addr> to re-enter the "10" server first, then the "15" server.
The servers would then be listed with the new "first-choice" server, that is:
Name Default Range
key <key-string> none (null) n/a
Specifies the optional, global "encryption key" that is also assigned in the TACACS+ server(s) that the switch will access
for authentication. This option is subordinate to any "per-server" encryption keys you assign, and applies only to accessing
TACACS+ servers for which you have not given the switch a "per-server" key. (See the host <ip-addr> [key <key-string>
entry at the beginning of this table.)
For more on the encryption key, see Using the Encryption Key on page 2-23 and the documentation provided with your
TACACS+ server application.
timeout <1. . 255> 5 sec 1 - 255 sec
Specifies how long the switch waits for a TACACS+ server to respond to an authentication request. If the switch does
not detect a response within the timeout period, it initiates a new request to the next TACACS+ server in the list. If all
TACACS+ servers in the list fail to respond within the timeout period, the switch uses either local authentication (if
configured) or denies access (if none configured for local authentication).
Name Default Range
First-Choice TACACS+ Server
!FishSecurity.book Page 18 Thursday, October 10, 2002 9:19 PM

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP ProCurve Switch 2650 and is the answer not in the manual?

HP ProCurve Switch 2650 Specifications

General IconGeneral
Switching Capacity13.6 Gbps
Forwarding Rate10.1 Mpps
LayerLayer 2
Form FactorRack-mountable
Flash Memory8 MB
Jumbo Frame SupportYes
Power SupplyInternal
ManagementWeb, CLI, SNMP
FeaturesVLAN support, IGMP snooping, QoS
Operating Temperature0°C to 45°C (32°F to 113°F)
Operating Humidity15% to 95% (non-condensing)
Ports48 x 10/100
MAC Address Table Size8, 000 entries

Related product manuals