Table 38 Error codes (part code 3305) (continued)
Severity
Level
Recommended ActionError MessageError
Number
Part
Code
WCorrect the settings, then retry the
operation.
An operation is specified for the
uninstalled VDEV.
10433305
EIf this problem persists, please contact
HP Technical Support.
An error occurred during SVP
processing.
10443305
WCorrect the specified content, and issue
the request again.
The specified Subsystem ID already
exists. Specify another SSID.
10453305
EIf this problem persists, please contact
HP Technical Support.
An error occurred during SVP
processing.
10493305
WCorrect the settings.The specified CU number cannot be set.10743305
ESpecify one or more than one operations
of Create LDEVs, Delete LDEVs in the VLL
operation.
In the VLL operation (Create LDEVs,
Delete LDEVs), there are some operations
which cannot be set together are
specified.
10753305
WCorrect the settings, then retry the
operation.
An operation is specified for the
uninstalled volume.
11013305
WCorrect the settings, then retry the
operation.
An operation is specified for the
uninstalled Parity Group.
11033305
WRequest the change of the Subsystem ID
along with the VLL operation.
Subsystem ID cannot be set alone.11043305
WCheck the settings.The number of volumes exceeds the
maximum that can be set.
11053305
WChange the volumes ID to specify, or
release the Parallel Access Volumes
setting.
The specified volume is currently used
by Parallel Access Volumes and is not
available for VLL operation.
11133305
WCheck the setting of the specified volume.The specified volume is used as a volume
of Volume Security for Mainframe.
11423305
WCheck the setting of the specified volume.The specified volume is used as a LUSE
volume.
11443305
WInstall the necessary program product
license key.
Error happened before the change was
processed. This functionality is not
available. Open Volume Management
is required.
16013305
WInstall the necessary program product.This functionality is not available. Virtual
LVI is required.
16023305
WWait for the maintenance to complete,
then retry the operation.
Maintenance operation is executed by
the SVP.
19003305
WCheck the setting of the specified volume.The specified volume contains Snapshot
pairs.
19103305
WSelect another volume.The specified volume contains Pool-VOLs.19113305
WCheck the setting.The setting cannot be made because the
specified LDEV is a remote command
device.
19133305
WCorrect the settings, then retry the
operation.
The number of V-VOL(s) has exceeded
the maximum number of V-VOL(s) that
can be set in a disk subsystem.
19143305
EIf this problem persists, please contact
HP Technical Support.
An error occurred during SVP
processing.
20043305
Part code 3305 105