Part code 7110
Table 63 Error codes (part code 7110)
Severity
Level
Recommended ActionError MessageError
Number
Part
Code
WCheck the capacity of S-VOL and T-VOL.
Specify a volume with the same capacity,
and retry the operation.
The T-VOL size differs from the specified
source volume size.
51157110
WYou cannot create the specified pair.
Delete the created pair, then retry the
operation.
You cannot create another pair, because
the number of pairs exceeds the
maximum.
51167110
WSelect the S-VOL, and retry the
operation.
The S-VOL is not selected.51197110
WSelect the T-VOL, and retry the operation.The T-VOL is not selected.51207110
WApply the data in the Preview list. To
stop the transaction, click [OK] and
continue the operation.
The data has been changed. If you select
another tab (page), the settings will be
discarded. Are you sure you want to
continue?
51217110
WGo on to the next operation.No data has been changed.51227110
WCheck the password.The password is invalid.51237110
WMultiple volumes cannot be processed
in the operation. Process one volume at
a time.
You cannot select more than one
operation at a time.
51247110
WSelect the target volume.No target volume is selected.51257110
WYou cannot create a pair for the
specified S-VOL. Delete the created pair,
and retry the operation.
The number of pairs exceeds the
maximum.
65047110
EPlease contact HP Technical Support.Unregistered error code.73107110
WWait a while, and retry the operation.
If the same error occurs despite retrying,
please contact HP Technical Support.
The settings could not be applied.73117110
EPlease contact HP Technical Support.The password could not be acquired.73127110
EPlease contact HP Technical Support.Error details not available.73137110
EIf this problem persists, please contact
HP Technical Support.
An error occurred during SVP
processing.
If this problem persists, please contact
HP Technical Support.
74407110
ERetry the operation. If you get the same
message again, reboot the PC. If
necessary, please contact HP Technical
Support.
A time-out error occurred. Please wait
for the subsystem to recover to the
normal condition, and then retry the
operation.
80017110
EPlease contact HP Technical Support.An internal logic contradiction occurred.85347110
iSpecify the volume of the supported
emulation type.
The emulation type is invalid.85687110
WCheck the error code in Preview list.Some settings could not be applied
normally. Refer to the error code.
86587110
WCheck the contents, and retry.There is no volume.86597110
iThe operation ended normally. Execute
the next operation.
The requested operation has completed.90027110