Table 62 Error codes (part code 7105) (continued)
Severity
Level
Recommended ActionError MessageError
Number
Part
Code
WThe specified operation cannot be
executed in the current pair
configuration. Specify volumes other than
FICON(R) Data Migration source volume
for T-VOL, and then retry the operation.
The command has been rejected
because the T-VOL of the specified pair
is a FICON(R) Data Migration Source
Volume.
687767105
WThe specified operation cannot be
executed to FICON(R) Data Migration
source volume. Specify a volume other
than FICON(R) Data Migration source
volume, and then retry the operation.
The command has been rejected
because the specified volume is a
FICON(R) Data Migration Source
Volume.
687777105
WDelete the Continuous Access
Synchronous pair or Continuous Access
Journal pair that is using Thin
Provisioning volumes, then retry the
operation.
The initialize function cannot be executed
because a Continuous Access
Synchronous pair or a Continuous
Access Journal pair is created by using
Thin Provisioning volumes.
688147105
WUse another CTG, or release the pair of
Snapshot where the specified CTG is in
use.
The command has been rejected
because the specified CTG is used by
Snapshot.
688327105
WUse another CTG, or release the pair of
Business Copy Z where the specified
CTG is in use.
The command has been rejected
because the specified CTG is used by
Business Copy Z.
688337105
WUse another CTG, or release the pair of
Business Copy where the specified CTG
is in use.
The command has been rejected
because the specified CTG is used by
Business Copy.
688347105
WSpecify the volume not used as S-VOL of
SI Operation for Mainframe Fibre Data
Migration, or retry the operation after
deleting the current pair.
The SI Operation for FICON(R) Data
Migration failed because more than one
T-VOL was assigned for the specified
S-VOL.
688547105
WSpecify another volume.The operation failed because the
emulation type of the specified S-VOL
was 3390-V.
780697105
WSpecify another volume.The operation failed because the
emulation type of the specified T-VOL
was 3390-V.
780707105
WSpecify another volume.The operation failed because the
emulation type of the specified volume
was 3390-V.
780717105
WSpecify another volume.The operation failed because the
emulation type of the specified S-VOL
was 3390-A.
780727105
WSpecify another volume.The operation failed because the
emulation type of the specified T-VOL
was 3390-A.
780737105
WSpecify another volume.The operation failed because the
emulation type of the specified volume
was 3390-A.
780747105
266 Message (part code group 7nnn)