Table 53 Error codes (part code 6505) (continued)
Severity
Level
Recommended ActionError MessageError
Number
Part
Code
WCheck the serial number and the
controller ID of this remote storage
system and already registered remote
storage systems, then specify the correct
values.
If the specified values are correct, check
the cable connection of the remote
storage system. If the problem persists,
please contact HP Technical Support.
The serial number or the controller ID of
the remote subsystem is incorrect.
581006505
WRefresh the window, and check the pair
status.
The pair status is incorrect.581016505
EThe pair status may be different in the
primary storage and the secondary
storage system. Wait for a while, then
retry the operation. Contact the support
center when the pair status of the pair
does not match between the primary and
the secondary storage system.
In the volume attached to Fujitsu OS, the
pair cannot be created by specifying
System for Timer Type.
Specify Local for Timer Type, then retry
the operation.
An internal error occurred.581026505
WCheck the status of the specified
secondary data volume from the
mainframe host.
The specified secondary data volume is
a reserve volume of a mainframe host.
581036505
WCheck the status of the specified
secondary data volume from the
mainframe host.
The specified secondary data volume is
already used by Compatible XRC.
581046505
WContinuous Access Journal or Continuous
Access Journal Z must be installed in
both the local and remote storage
systems when you create paths or pairs
with Continuous Access Journal or
Continuous Access Journal Z. Install
Continuous Access Journal or Continuous
Access Journal Z to the remote storage
system.
Continuous Access Journal or Continuous
Access Journal Z is not installed in the
remote storage system.
581056505
WConfirm the following items about the
specified primary data volume and
secondary data volume.
If the capacity of primary data volume
and secondary data volume matches.
In the case of LUSE volume, if the
capacity of each volume combined
in LUSE matches each other.
If the current microcode version
supports the specified data volume
capacity.
The operation failed because the
specified data volumes were in one of
the following status:
The capacity does not match between
the primary and the secondary data
volumes.
LUSE volume is specified for the
primary and the secondary data
volumes, and the capacity of each
volume combined in LUSE does not
match each other.
The specified capacity of the
secondary data volume is not
supported by the current microcode
version.
581066505