Table 59 Error codes (part code 7005) (continued)
Severity
Level
Recommended ActionError MessageError
Number
Part
Code
WSpecify another volume.The specified volume is a volume of
using two mirrors, which are included in
3DC cascade, 3DC multi target, or Delta
resync configuration. The operation for
this volume failed due to one of the
following reasons.
• The specified volume was used by
Delta resync of Continuous Access
Journal.
• The specified volume was used by a
data volume of Continuous Access
Journal.
689247005
WAssociate the specified Thin Provisioning
volume with a pool, then retry the
operation.
The command was rejected, because the
Thin Provisioning volume specified as
P-VOL was not associated with a pool.
750027005
WAssociate the specified Thin Provisioning
volume with a pool, then retry the
operation.
The command was rejected, because the
Thin Provisioning volume specified as
S-VOL was not associated with a pool.
750037005
WAssociate the specified Thin Provisioning
volume with a pool, then retry the
operation.
The command was rejected, because the
Thin Provisioning volume specified as a
reserved volume was not associated with
a pool.
750047005
WSet an LU path to the specified P-VOL,
then retry the operation.
The command was rejected, because no
LU path was set to the volume specified
as P-VOL.
750057005
WSet an LU path to the specified P-VOL,
then retry the operation.
The command was rejected, because no
LU path was set to the volume specified
as S-VOL.
750067005
WSet an LU path to the specified P-VOL,
then retry the operation.
The command was rejected, because no
LU path was set to the volume specified
as a reserved VOL.
750077005
WCheck the microcode version of the
storage system.
The operation failed because the current
microcode version does not support the
capacity of specified P-VOL.
780537005
WCheck the microcode version of the
storage system.
The operation failed because the current
microcode version does not support the
capacity of specified S-VOL.
780547005
WCheck the microcode version of the
storage system.
The operation failed because the current
microcode version does not support the
capacity of specified reserved volume.
780557005
Part code 7005 249