EasyManua.ls Logo

HP StorageWorks SN6000

HP StorageWorks SN6000
330 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
HP StorageWorks SN6000 Fibre Channel Switch Command Line Interface Guide 107
The following is an example of a full-text email, including profile and SNMP contact information:
From: john.doe@work.com [mailto:john.doe@work.com]
Sent: Wednesday, July 25, 2007 5:03 PM
Subject: [CallHome: Test] Alarm generated on Switch_8
------------ Event Details
SwitchName: Switch_8_83.215
SwitchIP: 10.20.30.40
SwitchWWN: 10:00:00:c0:dd:0c:66:f2
Level: Alarm
Text: CALLHOME TEST PROFILE MESSAGE
ID: 8B00.0002
Time: Wed Jul 25 17:02:40.343 CDT 2007
------------ Switch Location
Room 123; Rack 9; Bay 3
------------ Contact Information
George Smith
12345 4th Street, City, State
952-999-9999
george.smith@work.com
Technical support interface
The Tech_Support_Center profile provides a way to collect and send switch status and trend data
periodically by email to specified technical support resources. To use this feature, you must create a profile
named Tech_Support_Center. The capture command enables you to add instructions to the
Tech_Support_Center profile to specify the frequency with which to email the collected data. For more
information, see ā€Adding a data capture configurationā€ (page 114).

Table of Contents

Other manuals for HP StorageWorks SN6000

Related product manuals