EasyManua.ls Logo

HP StorageWorks SN6000

HP StorageWorks SN6000
330 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
HP StorageWorks SN6000 Fibre Channel Switch Command Line Interface Guide 265
show postlog
Description Displays the power-on self test log, which contains results from the most recently failed power-on self
test (POST).
Authority None
Syntax
show postlog
or
show post log
Examples The following is an example of the show postlog command:
SN6000 FC Switch #> show postlog
Queue: POST
Sequence Count: 467
Success Count: 452
Failed Count: 42
Records: 53
Record: 1 of 53
Time: day mmm dd hh:mm:ss yyyy
Sequence Number: 5
Consecutive Passes: 5
Record: 2 of 53
Time: day mmm dd hh:mm:ss yyyy
Sequence Number: 6
Test: TEST_SUITE_POST (0x13)
Subtest: TEST_STATIC_PORTADDR (0x72)
Fault Code: DIAGS_ERR_CPORT_VERIFY (0x34)
Loops: 0
Blade/Asic: 0/0
Register Address: 0x00000005
Received Data: 0x0082202b
Expected Data: 0x00a2202b
.
.
.

Table of Contents

Other manuals for HP StorageWorks SN6000

Related product manuals