198 Command Reference
The following is an example of the set config port command for an XPAK port:
SN6000 FC Switch #> admin start
SN6000 FC Switch (admin) #> config edit
SN6000 FC Switch (admin-config) #> set config port 20
A list of attributes with formatting and current values will follow.
Enter a new value or simply press the ENTER key to accept the current value.
If you wish to terminate this process before reaching the end of the list
press 'q' or 'Q' and the ENTER key to do so.
Configuring Port Number: 20
------------------------
AdminState (1=Online, 2=Offline, 3=Diagnostics, 4=Down) [Online]
LinkSpeed (10=10Gb/s, 20=20Gb/s,A=Auto) [Auto ]
PortType (G, F) [G ]
SymPortName (string, max=32 chars) [20G-20]
DeviceScanEnable (True / False) [True ]
ForceOfflineRSCN (True / False) [False ]
AutoPerfTuning (True / False) [True ]
MSEnable (True / False) [True ]
IOStreamGuard (Enable / Disable / Auto) [Auto ]
Finished configuring attributes.
This configuration must be saved (see config save command) and
activated (see config activate command) before it can take effect.
To discard this configuration use the config cancel command.
See also config, page 136
show config port, page 236

Table of Contents

Other manuals for HP StorageWorks SN6000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP StorageWorks SN6000 and is the answer not in the manual?

HP StorageWorks SN6000 Specifications

General IconGeneral
BrandHP
ModelStorageWorks SN6000
CategorySwitch
LanguageEnglish

Related product manuals