HP StorageWorks SN6000 Fibre Channel Switch Command Line Interface Guide 275
Examples The following is an example of the show switch command:
SN6000 FC Switch #> show switch
Switch Information
------------------
SymbolicName SN6000 FC Switch
SwitchWWN 10:00:00:c0:dd:00:bc:56
BootVersion Vx.x.x.x-0 (day month date time year)
CreditPool 0
DomainID 19 (0x13)
FirstPortAddress 130000
FlashSize - MBytes 128
LogFilterLevel Critical
MaxPorts 20
NumberOfResets 15
ReasonForLastReset PowerUp
ActiveImageVersion - build date Vx.x.x.0 (day month date time year)
PendingImageVersion - build date Vx.x.x.0 (day month date time year)
ActiveConfiguration default
AdminState Online
AdminModeActive False
BeaconOnStatus Off
OperationalState Online
PrincipalSwitchRole False
POSTFaultCode 00000000
POSTStatus Passed
TestFaultCode 00000000
TestStatus NeverRun
BoardTemp (1) - Degrees Celsius 32
SwitchTemperatureStatus Normal
See also set config switch, page 201