EasyManuals Logo
Home>HP>Adapter>XP

HP XP User Manual

HP XP
148 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #118 background imageLoading...
Page #118 background image
Explanation
In the XP P9500/XP7, PSUS is not supported.
Recommended action
Create pair status PAIR using Storage Management Software.
E200204F
Message
EndPrepareSnapshots abnormal end.
Explanation
A defect was detected while processing EndPrepareSnapshots I/F.
Recommended action
Reference the VSS Provider log files and any other error messages, and take the corresponding
action.
E2002050
Message
Unable to find an S-Vol for the P-Vol LU: [LU# of P-VOL].
Explanation
S-VOL for P-VOL is not found.
Recommended action
Create an S-VOL corresponding to the P-VOL, and make the pair status PAIR.
E2002052
Message
No FC HBAs or iSCSI initiators available on the local server.
Explanation
The disk array system is not connected to HBA of the server.
Recommended action
(1)The server configuration might not be supported in the virtual environments. With reference
to Table2.3.2-1, confirm whether the configuration of the server is satisfied.
(2)In the case of FC environment, confirm that the FC cables and HBA board on the backup
server are connected properly.
(3)In the case of iSCSI environment, confirm that Initiator iSCSI Name at the backup server
is being set properly.
(4) In case of using the VMware Gust to Guest Backup (FC) function, confirm that WWN of
ESXi is used in the configuration file (see Table 3.2.1-2).
E2002053
Message
Serial number: [serial number]: unable to get the device object.
118 Troubleshooting