For details, see the HPE XP7 dynamic link manager software user's guide (for Windows(R)
in the Hewlett Packard Enterprise Software manual. Refer to the descriptions of Windows
event logs and the messages that HDLM outputs.
Event IDSourceLog type
32787DLMManagerApplication
32790DLMManager
32794DLMManager
20781hdlmdsmSystem
• [VDS Service related]
Event IDSourceLog type
1VDS Basic ProviderSystem
1Virtual Disk ServiceSystem
The operative restrictions of the concurrence configuration change for the equivalence disk array
system
In disk array system specifications, a concurrence configuration change is executed for the
equivalent resource, unexpected configuration change is executed each other and the expected
configuration may not be made.
Therefore, for the resource that VSS Provider/GUI tool changes configuration of, the following
operative restrictions are necessary.
• Do not execute a concurrence configuration change from other applications (Storage
Management Software and so on).
• Make out the schedule not to execute a concurrence configuration change using VSS Provider
/GUI tool from other servers.
• Restart VSS Provider/GUI tool when you change the setting of a priced option in the disk
array system.
A volume status at the time of ResyncLuns abnormal finish
P-VOL remains in an off-line status to protect the consistency of data when a failure occurs in
restore processing by ResyncLuns.
Make target LUN an online status from Server Manager -> Disk Management as needed.
For details, visit the following.
http://support.microsoft.com/kb/2668865
Specifying WWN of the import server from the configuration file
VSS Provider executes the import processing by obtaining WWN of HBA on the secondary VOL
import server. If WWN is not available from HBA due to any reason, you can specify WWN of
the import server using “WWN of ESXi” specified option of the configuration file, see “Setup files”
(page 38).
32 Environmental Prerequisites