133
Record Route : Enabled Record Label : Enabled
FRR Flag : Enabled Bandwidth Protection : Disabled
Backup Bandwidth Flag: Disabled Backup Bandwidth Type: -
Backup Bandwidth : -
Bypass Tunnel : No Auto Created : No
Route Pinning : Disabled
Retry Limit : 10 Retry Interval : 2 sec
Reoptimization : Disabled Reoptimization Freq : -
Backup Type : None Backup LSP ID : -
Auto Bandwidth : Disabled Auto Bandwidth Freq : -
Min Bandwidth : - Max Bandwidth : -
Collected Bandwidth : -
5. Configure a bypass tunnel on Switch B (the PLR):
# Configure an explicit path for the bypass tunnel.
[SwitchB] explicit-path by-path
[SwitchB-explicit-path-by-path] nexthop 3.2.1.2
[SwitchB-explicit-path-by-path] nexthop 3.3.1.2
[SwitchB-explicit-path-by-path] nexthop 3.3.3.3
[SwitchB-explicit-path-by-path] quit
# Create MPLS TE tunnel interface Tunnel 5 for the bypass tunnel.
[SwitchB] interface tunnel 5 mode mpls-te
[SwitchB-Tunnel5] ip address 11.1.1.1 255.255.255.0
# Specify the tunnel destination address as LSR ID of Switch C.
[SwitchB-Tunnel5] destination 3.3.3.3
# Specify the tunnel signaling protocol as RSVP-TE.
[SwitchB-Tunnel5] mpls te signaling rsvp-te
# Specify the explicit path to be used as by-path.
[SwitchB-Tunnel5] mpls te path preference 1 explicit-path by-path
# Set the bandwidth that the bypass tunnel can protect.
[SwitchB-Tunnel5] mpls te backup bandwidth un-limited
[SwitchB-Tunnel5] quit
# Bind the bypass tunnel to the protected interface.
[SwitchB] interface vlan-interface 2
[SwitchB-Vlan-interface2] mpls te fast-reroute bypass-tunnel tunnel 5
[SwitchB-Vlan-interface2] quit
# Execute the display interface tunnel command on Switch B to verify that the tunnel interface
Tunnel 5 is up. (Details not shown.)
6. Configure a static route on Switch A to direct the traffic destined for subnet 100.1.2.0/24 to
MPLS TE tunnel 4.
[SwitchA] ip route-static 100.1.2.0 24 tunnel 4 preference 1
420BVerifying the configuration
# Display LSP entries on each switch to verify that Switch B and Switch C each have two CRLSPs
and the bypass tunnel backs up the primary CRLSP.
[SwitchA] display mpls lsp
FEC Proto In/Out Label Interface/Out NHLFE
1.1.1.1/4/61400 RSVP -/1245 Vlan1
2.1.1.2 Local -/- Vlan1

Table of Contents

Other manuals for HPE FlexFabric 5950 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HPE FlexFabric 5950 Series and is the answer not in the manual?

HPE FlexFabric 5950 Series Specifications

General IconGeneral
BrandHPE
ModelFlexFabric 5950 Series
CategorySwitch
LanguageEnglish

Related product manuals