Collected Bandwidth : -
NOTE:
If you execute the display mpls te tunnel-interface command immediately after an FRR, you can
see two CRLSPs in up state. This is because FRR uses the make-before-break mechanism to set
up a new LSP, and the old LSP is deleted after the new one has been established for a while.
# Verify that the bypass tunnel is in use on Switch B.
[SwitchB] display mpls lsp
FEC Proto In/Out Label Interface/Out NHLFE
1.1.1.1/4/61400 RSVP 1136/3 Tun5
2.2.2.2/5/30914 RSVP -/1149 Vlan4
3.2.1.2 Local -/- Vlan4
# On the PLR, configure the interval for selecting an optimal bypass tunnel as 5 seconds.
[SwitchB] mpls te
[SwitchB-te] fast-reroute timer 5
[SwitchB-te] quit
# On the PLR, bring up the protected interface VLAN-interface 2.
[SwitchB] interface vlan-interface 2
[SwitchB-Vlan-interface2] undo shutdown
# Execute the display interface tunnel 4 command on Switch A to display information about the
primary CRLSP. The output shows that the tunnel interface is in up state. (Details not shown.)
# Wait for about 5 seconds, execute the display mpls lsp verbose command on Switch B. The
output shows that Tunnel 5 is bound to interface VLAN-interface 2 but not in use. (Details not
shown.)
# Execute the display ip routing-table command on Switch A. The output shows a static route entry
with interface Tunnel 4 as the output interface. (Details not shown.)
203BAuto FRR configuration example
421BNetwork requirements
Use RSVP-TE to set up a primary CRLSP that explicitly uses path Switch A—Switch B—Switch
C—Switch D.
Configure auto FRR on Switch B to automatically set up bypass tunnels for the primary CRLSP.
Configure BFD for RSVP-TE between Switch B and Switch C. When the link between Switch B and
Switch C fails, BFD can detect the failure quickly and notify RSVP-TE of the failure, so RSVP-TE can
switch traffic to the bypass tunnel.

Table of Contents

Other manuals for HPE FlexFabric 5950 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HPE FlexFabric 5950 Series and is the answer not in the manual?

HPE FlexFabric 5950 Series Specifications

General IconGeneral
BrandHPE
ModelFlexFabric 5950 Series
CategorySwitch
LanguageEnglish

Related product manuals