Chapter 10 Parameter Shenzhen Hpmont Technology Co., Ltd.
- 88 - HD09-S Series User Manual V1.1
Ref. Code
Function
Setting Range
Default
Unit
Attribute
Setting
F00.13
Original operation
frequency digital setting
0.00Hz - F00.08 50.00Hz 0.01Hz
F00.14
UP / DOWN digital setting
control
Unit: Storage option of set frequency
when power down
0: Not saved
1: Save in F00.13
Ten: Options of set frequency in stop
0: Frequency hold
1: The set frequency returns to F00.13
when stopped
Hundred: Options of set frequency in
communication
0: Not saved
1: Save in F00.13
Thousand: Options of set frequency in
frequency channel switching
0: Do not save
1: Save
1001 1
×
F00.15
Inching operation
frequency digital setting
0.00Hz - F00.08 5.00Hz 0.01Hz
F00.17
Running direction
selection
0: Same direction
1: Contrary direction
0 1
×
F00.18 Anti-REV operation
0: Reverse allowed
1: Do not REV
0 1
×
F00.19
Dead time between
positive and negative
rotation
0.0 - 3600.0s 0.0s 0.1s
×
F00.20
External keypad
potentiometer enabled
0: Enable
1: Invalid
0 1
F01: Parameter Protection Function
F01.00 User password 00000 - 65535 00000 1
F01.01 Menu mode selection
0: Standard menu mode
1: Verifying menu mode
0 1
F01.02
Function code parameter
initialization (parameter
download)
0: No action
1: Restore the factory parameter
0 1
×