Loading...
Figure 9-6 Appearance of the PGND cable
Table 9-2 Technical specifications of the power cable and PGND cable
Wire Related Parameter Terminal Related Parameter
Electronic/Electric wire, 450 V/750 V, H07Z,
K, 4 mm
2
(0.006 in.
2
), yellow green, fire
resistant cable with low smoke and no
halogen
General terminal, OT, 6 mm
2
(0.009 in.
2
), tin
plating, pre-insulated ring terminal,
12-10AWG, yellow
9.2 Management Cables
On the ATN 950B, Ethernet cables are used to input and output NM signals.
The management cables for the ATN 950B include Ethernet cables.
Ethernet cables are classified into straight-through cables and crossover cables, and are used for
communication between the equipment and the NMS computer. The NM interface on the
equipment is adaptive to a straight-through cable or a crossover cable.
Figure 9-7 shows an RJ45 connector used at the end of the Ethernet cable.
When the cable is connected to the ETH/OAM interface, the pin assignment of the RJ45
connector is as listed in Table 9-3.
Table 9-4 lists the technical specifications of the Ethernet cable.
Figure 9-7 RJ45 connector
PIN#1
PIN#8
ATN 950B Multi-service Access Equipment
Hardware Description 9 Cables
Issue 03 (2012-07-23) Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.