Table 3-29 Attributes of the AUX interface
Attribute Description
Connector type RJ45
Working mode Duplex UART
Electrical
characteristics
RS-232
Baud rate The default value is 9600 bit/s. The value can be configured.
Data equipment
type
DTE (Data Terminal Equipment)
Cable
specification
8-core shielded cable
Table 3-30 lists the external clock interface attributes.
Table 3-30 Attributes of the external clock interface
Attribute Description
Connector type RJ45
Cable
specification
120-ohm clock shielded cable
Standard
compliance
G.703
Specifications
Table 3-31 lists the specifications of the MPUK.
Table 3-31 Specifications of the MPUK
Item Specification
Silkscreen of the board
name
CX-MPUK
Typical power
consumption
20 W
Heat dissipation 64.9 BTU/hour
Weight 0.6 kg ( 1.32 lb )
Dimensions (H x W x D) 20 mm x 194 mm x 226 mm (0.79 in. x 7.64 in. x 8.90 in. )