Interface
Name
Interface Type Description
CLK clock
interface
RJ45 One RJ45 interfaces. It is used to input one
channel or output one channel 2-Mbit/s clock
signals, or one channel 2-MHz clock signals.
RS485 interface RJ45 Used to connect to the monitoring interface
on the external AC power supply module
l Attributes of the interfaces on the MPU
Table 3-27 lists the 10Base-T/100Base-TX/1000Base-T-RJ45 interface attributes.
Table 3-27 Attributes of the 10Base-T/100Base-TX/1000Base-T-RJ45 interface
Attribute Description
Connector type RJ45
Working mode Half-duplex or full-duplex mode
Standard
compliance
IEEE 802.3-2002
Cable
specification
Super category 5 Shielded Twisted Pair (STP) cables recommended in
the case of 1000 Mbit/s
Table 3-28 lists the console interface attributes.
Table 3-28 Attributes of the console interface
Attribute Description
Connector type RJ45
Working mode Duplex Universal Asynchronous Receiver/Transmitter (UART)
Electrical
characteristics
RS-232
Baud rate The default value is 9600 bit/s. The value can be configured.
Data equipment
type
Data Circuit-terminating Equipment (DCE)
Cable
specification
8-core shielded cable
Table 3-29 lists the AUX interface attributes.
HUAWEI CX600-X1-M/CX600-X2-M Series Metro
Services Platform
Hardware Description
3 CX600-X2-M16 Hardware Description
Issue 03 (2014-04-30) Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
85