Figure 8-27 Network connections
The MM910 management port is provided by two modes.
● An Ethernet port on the switch module in slot 2X or 3X can be used as the MM910
management port. However, if a CX910/CX911/CX912/CX913/CX915 is in slot 2X or 3X,
only a GE port can be used; if a CX920 is in slot 2X or 3X, only a 10GE port can be
used; if a CX916/CX916L/CX930 is in slot 2X or 3X, only a 25GE port can be used. If a
CX110/CX111/CX310/CX311/CX312/CX320/CX710 is in slot 2X or 3X, any port can be
used. The CX910/CX911/CX912/CX913 are not recommended for providing the
management network port of the management module.
● The MGMT port on the MM910 panel can be used as the MM910 management port.
● For MM910 (U54) 2.25 or earlier, the port on the switch module in slot 2X or 3X is
used as the management network port by default. In this case, do not connect the
MGMT port on the MM910 and the port on the switch module to the same network
at the same time, otherwise, a network storm occurs and the network is interrupted.
For MM910 (U54) 2.26 or later, the MGMT port is used as the management network
port by default. For details about how to query the version, see the
MM910
Management Module V100R001 User Guide
.
● You can run the outportmode command to change the mode in which the MM910
management port is provided. For details, see "Querying and Setting the Network Port
Out Mode (outportmode)" in the
MM910 Management Module V100R001
Command Reference
Step 2 Set the IP address and subnet mask or route information for the local PC so that
the local PC can communicate with the MM910 properly.
Step 3 On the menu bar of Internet Explorer, choose Tools > Internet Options.
The Internet Options dialog box is displayed.
This section uses a PC running Windows 7 and Internet Explorer 8.0 as an example.
Huawei Servers
Troubleshooting 8 Common Operations
Issue 20 (2020-09-25) Copyright © Huawei Technologies Co., Ltd. 151