switch modules are not stacked, log in to each switch module and repeat the
preceding log collection procedure.)
[ftp]mkdir swi2
[ftp]cd swi2
[ftp]mput 2#ash:/logle/*
[ftp]cd ..
[ftp]quit
221 Windows FTP Server (WFTPD, by Texas Imperial Software) says goodbye
<HUAWEI>
NO TE
When you use the mput command in the FTP CLI, 2#ash:/ indicates the ash
root directory of the switch module with the stack ID 2. You can obtain the stack
ID and role information by using the display stack command.
The ash root directory of the master switch module in a stack is ash:/.
If multiple switch modules are displayed after running the display stack
command, obtain the log le of each switch module in the logle directory.
4. View the log le in the FTP directory on the PC.
----End
4.4.2.5 Using the Web Tools Page of a Switch Module to Collect FC
Switching Plane Information (MX510)
Operation Scenario
Use Web Tools page of a switch module (MX510) to collect information about the
FC switching plane.
This section applies to the CX311, CX911, and CX915.
Prerequisites
Conditions
The connection between the management IP address of the FC switch module
and the server IP address is normal.
You have logged in to the Ethernet switching plane Web Tools page. For
details, see 8.10 Logging In to the Web Tools of the MX510.
Data
Table 4-7 Data list
Parameter
Example Value
IP address 192.168.1.100
Subnet mask 255.255.255.0
Default gateway 0.0.0.0
Huawei Servers
Troubleshooting 4 Collecting Information
Issue 20 (2020-09-25) Copyright © Huawei Technologies Co., Ltd. 28