NO TICE
If you need to disconnect the service terminal or server power after logging in to
the SOL screen, exit the SOL screen rst. Otherwise, re-logging in to the SOL
screen will fail.
Step 3 Enter the user name and password.
The screen for selecting a slot number is displayed.
Log in Success!
*=====================================================================================
======================
please input the SOL Blade1~Blade16(1 ~ 16), Blade1A~Blade16A(17 ~ 32), Swi1~Swi4(33 ~ 36) and
COM#(n)
press Ctrl+R to return
*=====================================================================================
======================
Blade1~Blade16(1 ~ 16)
Blade1A~Blade16A(17 ~ 32)
Swi1~Swi4(33 ~ 36)
Please input your choice:
The numbers in the preceding information are described as follows:
1 to 32 indicate the compute nodes in slots 1 to 32, respectively.
33 to 36 indicate the switch modules in slots 1E, 2X, 3X, and 4E, respectively.
Step 4 Enter the slot number of the compute node, passthrough module, or switch
module, and press Enter.
If you enter a compute node slot number, the following serial port
information is displayed:
1 systemcom
2 RAIDcom
3 BMCcom
4 Exboardcom
Or
1 SYS COM
2 BMC COM
Or
1 systemcom
2 BMCcom
If you enter a switch module slot number, the following serial port
information is displayed:
1 BMCcom
2 fabriccom
3 basecom
4 FCcom
Or
1 BMCcom
2 fabriccom
Or
1 BMCcom
2 fabriccom
3 basecom
Huawei Servers
Troubleshooting 8 Common Operations
Issue 20 (2020-09-25) Copyright © Huawei Technologies Co., Ltd. 169