Loading...
NIC Type Chip
Mode
l
Port Status Network
Status
Operation
O The network
connection
is
unavailable.
1. Connect the port
to another switch
and network cable
to check whether
the original switch
and network cable
are normal.
2. Check whether the
NIC is operating
properly.
NOTE
For details, visit the ocial websites of the PCIe card vendors.
----End
Indicators Available Only on the RH5885 V2, RH5885 V3, and RH5885H V3
Table 5-11 Indicators for each module
Indicator
Status Meaning Diagnosis
Power indicator
on a memory riser
Steady green The memory riser
is on.
N/A
O The memory riser
is o.
Memory riser
fault indicator
Steady red A DIMM on the
memory riser is
faulty.
Locate the faulty
DIMM according
to the DIMM fault
locating indicator,
and replace the
faulty DIMM with
a spare one.
O All DIMMs on the
memory riser are
normal.
N/A
DIMM fault
locating indicator
Steady red The DIMM is
faulty.
After you remove
the memory riser
and hold down
the DIMM fault
locating button,
the indicator of
the faulty DIMM
turns on.
Huawei Servers
Troubleshooting 5 Diagnosing and Rectifying Faults
Issue 20 (2020-09-25) Copyright © Huawei Technologies Co., Ltd. 60