3.2 Environmental Specications
Table 3-2 Environmental specications
Category Specications
Temperature Operating temperature: 5°C to 35°C (41°F to 95°F)
(ASHRAE Class A2 compliant)
Storage temperature (≤ 72 hours): –40°C to +65°C
(–40°F to +149°F)
Long-term storage temperature (> 72 hours): 21°C
to 27°C (69.8°F to 80.6°F)
Maximum rate of temperature change: 20°C (36°F)
per hour, 5°C (9°F) per 15 minutes
NOTE
If a single fan is faulty:
The highest operating temperature supported is 30°C
(86°F).
If the power consumption of the processor is 125 W or
higher, the system performance may be
aected or a
temperature alarm may be generated.
When the server is congured with 6248R or 6258R
processors, the highest operating temperature is 30°C
(86°F).
The highest operating temperature varies depending on
the server
conguration. For details, see A.2 Operating
Temperature Limitations.
Relative humidity (RH,
non-condensing)
Operating humidity: 8% to 90%
Storage humidity (≤ 72 hours): 5% to 95%
Long-term storage humidity (> 72 hours): 30% to
69%
Maximum change rate: 20%/h
FusionServer Pro XH321 V5 Server Node
Maintenance and Service Guide 3 Product Specications
Issue 17 (2021-03-09) Copyright © Huawei Technologies Co., Ltd. 27