a. Log in to the iBMC WebUI.
For details, see 10.2 Logging In to the iBMC WebUI.
b. Choose Power > Power Control.
The Power Control page is displayed.
c. Click Power
O or Forced Power O.
A conrmation message is displayed.
d. Click OK.
The server starts to be powered o.
● Use the iBMC CLI.
a. Log in to the iBMC CLI.
For details, see 10.4 Logging In to the CLI.
b. Run the following command:
ipmcset -d powerstate -v 1
c. Type y or Y and press Enter.
● Use the Remote Virtual Console.
a. Log in to the Remote Virtual Console.
For details, see 10.3 Logging In to the Desktop of a Server.
b. On the KVM screen, click
or on the toolbar.
c. Choose Power O or Forced Power O.
A dialog box is displayed.
d. Click Yes.
8.3.3 Removing an XH321 V5
Procedure
Step 1 Determine the position of the server node in the chassis.
Figure 8-2 Positions and slot numbers of the XH321 V5 server nodes
Step 2 Power o the server node.
For details, see 8.3.2 Power-O Procedure.
Step 3 Remove the multi-port cable.
1. Press the two tabs on the multi-port cable connector. See (1) in Figure 8-3.
2. Remove the multi-port cable from the universal connector port (UCP) on the
server. See (2) in Figure 8-3.
FusionServer Pro XH321 V5 Server Node
Maintenance and Service Guide 8 Parts Replacement