Step 2 Remove the server node.
For details, see 8.3.3 Removing an XH321 V5.
Step 3 Place the server node on the ESD workstation.
Step 4 Take the component out of its ESD bag.
Step 5 Determine the position of the Avago SAS3004iMR RAID controller card.
Step 6 Install the Avago SAS3004iMR RAID controller card.
For details, see 8.4.20 Installing a PCIe Card.
Step 7 Install the M.2 FRU on the Avago SAS3004iMR RAID controller card.
For details, see 8.4.10 Installing an M.2 FRU on the Avago SAS3004iMR PCIe
RAID Controller Card.
Step 8 Install the server node.
For details, see 8.3.4 Installing an XH321 V5.
Step 9 Power on the server node.
For details, see 8.3.1 Power-On Procedure.
----End
8.4.9 Removing an M.2 FRU on the Avago SAS3004iMR PCIe
RAID Controller Card
The M.2 FRU on the Avago SAS3004iMR RAID controller card is hot swappable.
NO TE
The M.2 FRU on the Avago SAS3004iMR RAID controller card is hot swappable:
If the drive to be removed has no operating system installed, you can remove it
without powering o the server node.
If the drive to be removed has the operating system installed and is in a RAID array
with redundancy, and the removal does not cause a RAID array fault, you can
remove it without powering o the server node.
If the drive to be removed has the operating system installed but it is not in a RAID
array or it is in a RAID array without redundancy (for example, RAID 0), power o
the server node before removing it.
The M.2 FRU on the Avago SAS3004iMR RAID controller card supports RAID
conguration:
If the drive to be removed is not in a RAID array or is in a RAID array without
redundancy (for example, RAID 0), back up the data on the drive before removing
it.
If the drive to be removed is in a RAID array with redundancy and the removal
does not cause a RAID array fault, you do not need to back up data before
removing it.
Procedure
Step 1 Determine the positions and slots of the M.2 FRUs on the Avago SAS3004iMR
RAID controller card.
FusionServer Pro XH321 V5 Server Node
Maintenance and Service Guide 8 Parts Replacement
Issue 17 (2021-03-09) Copyright © Huawei Technologies Co., Ltd. 62