Figure 7-60 Power/Alarm indicators on a controller
1 Power indicator of the
controller
2 Alarm indicator of the controller
Step 9 Conrm the replacement.
1. Perform a post-replacement inspection.
a. If the FRU tool can identify the faulty controller before the replacement:
After the parts replacement, return to the SmartKit page and click
Replaced. Then complete the parts check after the replacement as
prompted.
b. If the FRU tool fails to identify the faulty controller before the
replacement:
Check the status of the controller Alarm indicator to determine whether
the controller is working properly. Figure 7-60 shows the location of the
indicators.
If the Alarm indicator is steady red, an alarm is generated on the
controller.
If the Alarm indicator is blinking red and the Power indicator is
blinking green, the controller is being located.
If the Alarm indicator is
o, the controller is working properly.
NO TICE
If the version of the newly installed controller is inconsistent with that of the
faulty controller, the controller will synchronize the version after the
replacement. This process takes about 30 minutes and the maximum duration
is 60 minutes. If the duration exceeds 60 minutes, contact Huawei technical
support. During the synchronization, do not remove the controller or power
o the storage system.
2. Check system status.
On the Parts Replacement page, click Inspection to check the system status
again. If any item fails inspection, rectify the fault based on the suggestions in
the inspection report.
OceanStor V5 Series
Parts Replacement 7 Replacing FRUs
Issue 15 (2019-12-30) Copyright © Huawei Technologies Co., Ltd. 200