Figure 7-112 Installing a disk
3. Ensure that the ejector lever is fastened to the chassis beam, and lower the
ejector lever to completely insert the spare part into the chassis. See step (2)
in Figure 7-112.
Step 3 Wait until the disk indicator turns normal, indicating that the disk is powered on.
----End
Follow-up Procedure
Log in to the quorum server.
1. Run the qsadmin command to check whether the
conguration page of the
quorum server software is displayed.
Q2qumrom:~ # qsadmin
start main!
Waiting for connecting to server...
admin:/>
If the preceding command output is displayed, go to 2.
If the preceding command output is not displayed, the arbitration
conguration information has been lost. In this case, reinstall and
congure the quorum server software.
For details, see the
BC&DR Solution Product Documentation (Active-Active
DCs)
.
2. Run the show server_ip command to check whether the connection between
the quorum server and storage devices is in Established state.
admin:/>show server_ip
Index Server IP Server Port
----- --------------- ---------------
1 192.168.6.31 30002
2 192.168.7.31 30002
Index Local IP Local Port Remote IP Remote Port State
----- --------------- --------------- --------------- --------------- ---------
0 192.168.6.31 30002 192.168.6.17 44510 Established
1 192.168.6.31 30002 192.168.6.18 36836 Established
2 192.168.7.31 30002 192.168.7.16 57416 Established
3 192.168.7.31 30002 192.168.7.28 49752 Established
If yes, the quorum server can work properly.