Figure 6-67 Installing a power module
Step 9 Wait approximately two minutes and check the status of the Running/Alarm
indicator on the BBU to determine whether the BBU has been successfully
installed. Figure 6-68 shows the location of the Running/Alarm indicator.
If the indicator is steady green or blinking green, the BBU has been
successfully installed.
If the indicator is steady red or o, the newly installed BBU is faulty, the BBU
slot is faulty, or the BBU is incorrectly installed.
Figure 6-68 Running/Alarm indicator on a BBU
OceanStor V5 Series
Parts Replacement 6 Replacing CRUs
Issue 15 (2019-12-30) Copyright © Huawei Technologies Co., Ltd. 71