a. Power off the server and remove the power cables.
b. Place the jumper cap on COM_SW pins. For details about the jumper position, see
2.6 Mainboard Layout.
c. Connect the power cables and power on the server.
Step 2 Use a serial cable to connect the terminal serial port and the server serial port.
Step 3 Open HyperTerminal and set the following parameters:
l Bits per second: 115200
l Data bits: 8
l Parity: None
l Stop bits: 1
l Flow control: None
Figure 9-5 shows the port settings.
Figure 9-5 HyperTerminal Properties
Step 4 Click Apply.
Step 5 Enter the user name and password to access the CLI.
----End
RH2288 V3 Server
User Guide
9 Common Operations
Issue 32 (2019-03-28) Copyright © Huawei Technologies Co., Ltd. 272