Figure 2-8 Working modes
Table 2-3 Working mode description
Working
Mode
Description
Standby The inverter enters standby mode when the external environment
does not meet the operating requirements. In standby mode:
The inverter continuously detects its operation status. Once the
operation conditions are met, the inverter enters operating
mode.
If the inverter receives a shutdown command or detects a fault
after startup, it enters shutdown mode.
Operating In operating mode:
The inverter converts DC power from PV strings into AC power
and feeds the power to the power grid.
The inverter tracks the maximum power point to maximize the
PV string output power.
If the inverter receives a shutdown command or detects a fault,
it enters shutdown mode.
If the inverter detects that the output power of PV strings does
not meet the requirements for grid-tied power generation and
no battery is used in the system, it enters standby mode.
If the PV modules receive no sunlight, the inverter enters
shutdown mode after the batteries discharge to the lower SOC
threshold.