Procedure
Step 1 Two persons are required to move the inverter with one person on both sides. Lift
the inverter from the packing case and move it to the
specied installation
position.
CA UTION
Move the inverter with care to prevent device damage and personal injury.
Do not hold the wiring terminals and ports at the bottom. Do not place the
inverter with the wiring terminals and ports touching the ground or other
supporting surface.
When you need to temporally place the inverter on the ground, use protection
material such as foam and paper underneath to prevent damage to its
enclosure.
----End
4.6 Installing an Inverter (Wall Mounting)
Procedure
Step 1 Determine the hole positions and mark them using a marker.
Step 2 Secure the mounting bracket.
NO TE
M6x60 expansion bolts are delivered with the SUN2000. If the length and amount of the
bolts do not meet installation requirements, prepare M6 stainless steel expansion bolts
by yourself.
The expansion bolts delivered with the inverter are used for solid concrete walls. For
other types of walls, prepare bolts by yourself and ensure that the wall meets the load
bearing requirements of the inverter.
Figure 4-6 M6 expansion bolt structure
SUN2000-(12K-25K)-MB0 Series
User Manual 4 Installation
Issue 01 (2023-04-30) Copyright © Huawei Digital Power Technologies Co., Ltd. 30

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Huawei SUN2000 MB0 Series and is the answer not in the manual?

Huawei SUN2000 MB0 Series Specifications

General IconGeneral
TypeString Inverter
Max Input Voltage1100 V
MPPT Voltage Range200 V - 1000 V
Number of MPPTs2
Max Input Current per MPPT26 A
Rated Output Frequency50 Hz / 60 Hz
Max Efficiency98.6%
Operating Temperature Range-25°C to +60°C
Protection DegreeIP65
CoolingNatural Convection
Power Factor Adjustment Range0.8 leading to 0.8 lagging
Cooling MethodNatural Convection
Protection LevelIP65
ModelSUN2000
Rated Output Voltage230 V / 400 V
Humidity0% - 100%