EasyManua.ls Logo

Huawei SUN2000 MB0 Series - System Maintenance; System Power-Off

Huawei SUN2000 MB0 Series
139 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
7 System Maintenance
D ANGER
Wear personal protective equipment and use dedicated insulated tools to avoid
electric shocks or short circuits.
WARNING
Before performing maintenance, power o the equipment, follow the
instructions on the delayed discharge label, and wait for a period of time as
specied to ensure that the equipment is not energized.
7.1 System Power-O
Precautions
WARNING
After the system is powered o, the inverter is still energized and hot, which
may cause electric shocks or burns. Therefore, wait for 5 minutes after power-
o
and then put on insulated gloves to operate the inverter.
Power o the system before maintaining optimizers and PV strings. Otherwise,
electric shocks may occur when the PV strings are energized.
Procedure
Step 1 Send a shutdown command on the app.
Step 2 Turn o the AC switch between the inverter and the power grid.
Step 3 Set the DC SWITCH to OFF.
SUN2000-(12K-25K)-MB0 Series
User Manual 7 System Maintenance
Issue 01 (2023-04-30) Copyright © Huawei Digital Power Technologies Co., Ltd. 86