Page #78 background image
LED Indicator Status Remarks Description
Blinking red
and green
alternately
Blinking slowly
(on for 1s and
o for 1s)
No communication with the
inverter:
Remove and then insert
the Smart Dongle.
Check whether the
inverter matches the
Smart Dongle.
Connect the Smart
Dongle to another
inverter.
Check whether the
Smart Dongle is faulty or
the USB port of the
inverter is faulty.
----End
6.2 Creating a Plant
6.2.1 Downloading the FusionSolar App
Method 1: Access https://solar.huawei.com using the mobile phone browser
and download the latest installation package.
Figure 6-2 Downloading the app
SUN2000-(12K-25K)-MB0 Series
User Manual 6 Power-On and Commissioning
Issue 01 (2023-04-30) Copyright © Huawei Digital Power Technologies Co., Ltd. 72

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Huawei SUN2000 MB0 Series and is the answer not in the manual?

Huawei SUN2000 MB0 Series Specifications

General IconGeneral
TypeString Inverter
Max Input Voltage1100 V
MPPT Voltage Range200 V - 1000 V
Number of MPPTs2
Max Input Current per MPPT26 A
Rated Output Frequency50 Hz / 60 Hz
Max Efficiency98.6%
Operating Temperature Range-25°C to +60°C
Protection DegreeIP65
CoolingNatural Convection
Power Factor Adjustment Range0.8 leading to 0.8 lagging
Cooling MethodNatural Convection
Protection LevelIP65
ModelSUN2000
Rated Output Voltage230 V / 400 V
Humidity0% - 100%
CommunicationRS485