Item Specication
Heat dissipation mode The fan module locates at the air
exhaust of the system.
Airow direction Air inlet from front and air outlet from
rear
Maximum number of 40GE ports 2
Maximum number of 10GE ports 12
Maximum number of electrical ports 16
Redundant power supply 1+1
Redundant fans 3+1
Noise at normal temperature (acoustic
power) [db(A)]
● USG6635E-AC (02352RQD): -
● USG6635E-DC (02352RQE): ≤72dbA
Long-term operating temperature
[°C(°F)]
Without hard disk driver: 0°C to 45°C
With hard disk driver: 5°C to 40°C
Storage temperature [°C(°F)] -40°C to 70°C
Long-term operating relative humidity
[RH]
5% RH to 95% RH, non-condensing
Storage relative humidity [RH] 5% RH to 95% RH, non-condensing
Long-term operating altitude [m(ft.)] Without hard disk driver: 0 m to 5000
m
With hard disk driver: 0 m to 3000 m
Storage altitude [m(ft.)] 0 m to 5000 m
● The width does not include the size of mounting ears.
● The height is 1U (1U = 1.75 inches, or about 44.45 mm), which is a height unit dened
in International Electrotechnical Commission (IEC) 60297 standards.
● Temperature and humidity are measured 1.5 m above the
oor and 0.4 m in front of the
rack when no protection plate exists before or after the rack.
● The operating temperature change rate of a device with HDDs must be less than or
equal to 20°C/hour.
4.1.20 USG6650E
HUAWEI USG6000E Series
Hardware Guide 4 Hardware Overview
Issue 08 (2022-04-20) Copyright © Huawei Technologies Co., Ltd. 276