138
7. Alarm List
Alarm
No.
Alarm Picture Cause Action
36
Horizontal mechanism can not
move to V channel in line position
Horizontal mechanism
has a problem.
Check linear motor and linear
guide. Because there is an
overload.
See 11-1 Mechanism
Drawing
Item17 : linear motor
Drawing NO : S24403-000X
Item5 : linear guide
Drawing NO : S04405-000X
37
V Channel in line limit switch
(LS-5)
detecting before Horizontal
mechanism move to V channel in
line position
(1) Metal scrap on the
surface of switch.
(2) Damaged switch.
(1) Cleanse the surface of
switch
(2) Replace switch.
See11-1 Mechanism Drawing
Item1: proximity switch-
V Channel in line limit switch
(LS-5)
Drawing NO : S21101-000X
38
Horizontal mechanism can not
move to Pushrod in line position
Horizontal mechanism
has a problem.
Check linear motor and linear
guide. Because there is an
overload.
See 11-1 Mechanism
Drawing
Item18 : linear motor
Drawing NO : S24403-000X
Item6 : linear guide
Drawing NO : S04405-000X