120786
Retaining Cap
120794
Nozzle
120853
Swirl Ring
120855
Electrode
* Piercing not recommended
Minimum inlet pressures remain at one setting of 140 psi (9.6 bar) for all material thicknesses.
Approximate pressures while cutting in RUN mode: PG1 49
PG2 33
Flow Rates @ 140 psi / 9.6 bar
(scfh / slh)
N
2
O
2
Preflow 211.4 / 5986 56.1 / 1589
Cutflow 200.6 / 5680 36.1 / 1036
3/16 130 .125 3 180 4570 .250 6 0.5
1/4 135 .125 3 160 4060 .250 6 1
3/8 135 .125 3 120 4050 .250 6 1.5
1/2 140 .125 3 80 2030 .250 6 2
5/8 140 .157 4 70 1780 .314 8 2
3/4 150 .250 6 50 1270 .500 12 2.5
7/8 160 .250 6 35 890 .500 12 2.5
1 165 .250 6 25 630 * * *
1-1/4 175 .250 6 20 510 * * *
ENGLISH
Material
Thickness
Plasma PlasmaShield Shield
MV1 MV2 MV3 MV4 MV5 MV6 MV7 PG1 PG2 PG1 PG2 inches Volts in. mm ipm mm/m in. mm seconds
Test
Preflow
Verify
(psi)
Test
Cutflow
Verify
(psi)
Arc
Voltage
Torch-to-Work
Distance
Cutting
Speed
Initial Pierce
Height
Pierce
Delay
Time
Test Preflow and Cutflow Adjust
(psi)
43 34 30 40 0 5 8 27 45 37 36
5 130 3 .125 4355 172 6 .250 0.5
6 135 3 .125 4301 169 6 .250 1
10 135 3 .125 2903 114 6 .250 1.5
12 140 4 .157 2151 85 6 .250 2
15 140 4 .157 1851 73 8 .314 2
20 145 5 .188 1210 48 12 .500 2.5
22 145 6 .250 898 35 12 .500 2.5
25 150 6 .250 645 25 * * *
30 160 6 .250 543 21 * * *
METRIC
Material
Thickness
Plasma PlasmaShield Shield
MV1 MV2 MV3 MV4 MV5 MV6 MV7 PG1 PG2 PG1 PG2 mm Volts mm in. mm/m ipm mm in. seconds
Test
Preflow
Verify
(psi)
Test
Cutflow
Verify
(psi)
Arc
Voltage
Torch-to-Work
Distance
Cutting
Speed
Initial Pierce
Height
Pierce
Delay
Time
Test Preflow and Cutflow Adjust
(psi)
43 34 30 40 0 5 8 27 45 37 36