EasyManua.ls Logo

Hypertherm HT4400 - Mild Steel 100 Amps

Hypertherm HT4400
195 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
HT4400 Instruction Manual f-5
2
Mild Steel
O
2
Plasma / O
2
-N
2
Shield
100 Amps
Flow Rates @ 120 psi (8.3 bar)
(scfh / slh)
N
2
O
2
Preflow 123.4 / 3492 38.2 / 1080
Cutflow 76.1 / 2154 68.4 / 1932
120786
Retaining Cap
120777
Nozzle
120783
Swirl Ring
120785
Electrode
Minimum inlet pressures remain at one setting of 120 psi (8.3 bar) for all material thicknesses.
Approximate pressures while cutting in RUN mode: PG1 77
PG2 17
1/8 125 .094 2 240 6100 .188 5 0.3
3/16 125 .125 3 180 4570 .250 6 0.5
1/4 130 .125 3 120 3050 .250 6 0.7
3/8 135 .157 4 85 2160 .314 8 0.9
1/2 135 .157 4 60 1520 .314 8 1.5
ENGLISH
Material
Thickness
Plasma PlasmaShield Shield
MV1 MV2 MV3 MV4 MV5 MV6 MV7 PG1 PG2 PG1 PG2 inches Volts in. mm ipm mm/m in. mm seconds
Test
Preflow
Verify
(psi)
Test
Cutflow
Verify
(psi)
Arc
Voltage
Torch-to-Work
Distance
Cutting
Speed
Initial Pierce
Height
Pierce
Delay
Time
Test Preflow and Cutflow Adjust
(psi)
36 4 2 3 24 13 17 3124 3517
3 125 2 .094 6462 255 5 .188 0.3
5 125 3 .125 4355 172 6 .250 0.5
6 130 3 .125 3226 127 6 .250 0.7
10 135 4 .157 2056 81 8 .314 0.9
12 135 4 .157 1613 64 8 .314 1.5
METRIC
Material
Thickness
Plasma PlasmaShield Shield
MV1 MV2 MV3 MV4 MV5 MV6 MV7 PG1 PG2 PG1 PG2 mm Volts mm in. mm/m ipm mm in. seconds
Test
Preflow
Verify
(psi)
Test
Cutflow
Verify
(psi)
Arc
Voltage
Torch-to-Work
Distance
Cutting
Speed
Initial Pierce
Height
Pierce
Delay
Time
Test Preflow and Cutflow Adjust
(psi)
36 4 2 3 24 13 17 3124 3517