Installation
3
128 810060 Instruction Manual XPR170
f. Connect the shield gas hose
(blue). Push the hose into
the connector until it stops,
approximately 13 mm
(0.5 inch).
This is a
push-to-connect fitting.
g. Connect plasma gas hose 2
(yellow). Push the hose into
the connector until it stops,
approximately 13 mm
(0.5 inch).
This is a push-to-connect
fitting.
h. Connect plasma gas hose 1
(black). Push the hose into
the connector until it stops,
approximately 13 mm
(0.5 inch).
This is a push-to-connect
fitting.
6. Install the torch mounting sleeve:
a. Move the the torch mounting sleeve in the direction of the torch.
b. Use your hands totighten the torch mounting sleeve connection.
A spanner wrench (104879) comes with all 4 of the consumable parts kits
(428616, 428617, 428618, 428619). Do not over tighten the torch
mounting sleeve if you use the spanner wrench to stabilize the torch
during mounting sleeve installation.
7. Reposition the collar on the torch-end of the torch lead:
a. Move the collar in the direction of the torch-end of the torch lead assembly.
Shield gas hose (blue)
Plasma gas hose 2
(yellow)
Plasma gas hose 1 (black)