Qualifications and Requirements
XPR300 Instruction Manual 809480 61
Bend radius requirements for hoses, cables, and leads
The following hoses, cables, and leads cannot bend beyond a
minimum bend radius of 15.25 cm (6 inches):
Torch lead
Pilot arc lead
Coolant hose set
Power cable
CAN cable
3-gas hose bundle for the Core gas connect console
5-gas hose bundle for the VWI or OptiMix gas connect console
Gas supply hoses
Maximum diameters for console-to-console lead sets
The connectors for the console-to-console lead sets have the following maximum diameters:
5.6 cm (2.2 in.) for the pilot arc / coolant-hose lead set
5.8 cm (2.3 in.) for the gas-hose set
For lengths, refer to Gas connect console to torch connect console
connections in Parts List on page 361.
15.25 cm
(6 in.)
Minimum bend radius
(measured inside diameter)
Example OptiMix pilot arc / coolant-hose lead set*
Example OptiMix gas-hose set*
* OptiMix assemblies shown as examples. The connectors on all console-to-console assemblies (Core, VWI,
and OptiMix) have the same diameter.