Diagnostics and Troubleshooting
XPR170 Instruction Manual 810060 267
Table 36 – Diagnostic codes
Diagnostic code
number and
category
Diagnostic code
name
Description Corrective action XPR action
Code cancels
with
500
Failure
GCC->Main CAN
t/o
The gas connect console
(Core, VWI, or OptiMix)
cannot receive
communications (at least
once-per-second) from the
main control PCB though the
CAN.
Refer to CAN codes (500 – 503, 510 – 513 for gas
connect console, 504, 514 for CAN cable and
jumper block, 507 – 508 for CAN network and bus,
600 – 602 for no CAN communication) on
page 302.
Shut down Remote on-off
501
Failure
Mix->Main CAN t/o The gas connect console
(Core, VWI, or OptiMix)
cannot receive
communications (at least
once-per-second) from the
main control PCB through
the CAN.
Shut down Remote on-off
503
Failure
TCC->Main CAN
t/o
The torch connect console
cannot receive
communications (at least
once-per-second) from the
main control PCB through
the CAN.
Shut down Remote on-off
504
Failure
Ch1->Main CAN
t/o
Chopper 1 cannot receive
communications (at least
once-per-second) from the
main control PCB through
the CAN.
Shut down Remote on-off
507
Failure
Main no CAN There is a problem with the
CAN network when power is
supplied to the cutting
system.
Refer to CAN codes (500 – 503, 510 – 513 for gas
connect console, 504, 514 for CAN cable and
jumper block, 507 – 508 for CAN network and bus,
600 – 602 for no CAN communication) on
page 302.
None Remote on-off
508
Error
CAN Busy The CAN bus is overloaded
(for 10 milliseconds or more).
None Remote on-off