Diagnostics and Troubleshooting
268 810060 Instruction Manual XPR170
510
Failure
Main->GCC CAN
t/o
The main control PCB cannot
receive communications (at
least once-per-second) from
the gas connect console
(Core, VWI, or OptiMix)
through the CAN.
Refer to CAN codes (500 – 503, 510 – 513 for gas
connect console, 504, 514 for CAN cable and
jumper block, 507 – 508 for CAN network and bus,
600 – 602 for no CAN communication) on
page 302.
Ramp down Remote on-off
511
Failure
Main->Mix CAN t/o The main control PCB cannot
receive communications (at
least once-per-second) from
the gas connect console’s
mix module through the CAN.
Ramp down Remote on-off
513
Failure
Main->TCC CAN
t/o
The main control PCB cannot
receive communications (at
least once-per-second) from
the torch connect console
through the CAN.
Ramp down Remote on-off
514
Failure
Main->Ch1 CAN
t/o
The main control PCB cannot
receive communications (at
least once-per-second) from
Chopper 1 through the CAN.
None Remote on-off
Diagnostic code
number and
category
Diagnostic code
name
Description Corrective action XPR action
Code cancels
with