EasyManua.ls Logo

Hypertherm XPR170 - Example Configurations for Consumables; Ferrous (Mild Steel) Example Configurations; Mild Steel - 50 a - O;Air

Hypertherm XPR170
428 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Installation
3
138 810060 Instruction Manual XPR170
Example configurations for consumables
Worn or damaged consumables can have a negative effect on cut quality. Examine the installed consumables at least
once daily, before system operation. For information about how to do this, refer to Examine the consumable parts on
page 241 in the Maintenance section of this manual.
Ferrous (mild steel) example configurations
Mild steel 30 A O
2
/O
2
* Consumables for mirror cutting only.
Mild steel 50 A O
2
/Air
* Consumables for mirror cutting only.
Water tube
420368
ElectrodeSwirl ringNozzle
420222420407
420620*
420225
Nozzle retaining
cap
420365
Shield
420228
420619*
420200
Shield retaining
cap
Water tube
420368
ElectrodeSwirl ringNozzle
420231420233
420768*
420234
Nozzle retaining
cap
420365
Shield
420237
420767*
420200
Shield retaining
cap

Table of Contents