Maintenance
7
248 810060 Instruction Manual XPR170
Figure 60 Face of a new electrode (note hafnium emitter and electrode pit)
If the electrode pit diameter extends beyond the hafnium (Figure 61), replace the electrode and
nozzle.
Figure 61 Wide electrode pit that extends beyond the hafnium
Electrode face
Electrode pit
Hafnium emitter